Nutter Tools
Nutter Tools

A free toolbox that runs in your browser. A tool for every job.

Your files never leave your device

Images

  • Convert images
  • Compress images
  • Resize images
  • Crop
  • Watermark

PDF & files

  • Merge PDFs
  • Split a PDF
  • Images to PDF
  • PDF to images
  • Remove photo location

Video & audio

  • Compress video
  • Convert video
  • Video to GIF
  • Convert audio
  • Trim audio

Everyday

  • QR codes
  • Passwords
  • Time zones
  • Unit converter
  • Word count
  • Webcam test

Developer

  • JSON formatter
  • Base64
  • Regex tester
  • Hashes
  • JWT decoder

Site

  • About
  • Contact
  • Settings
  • Privacy
  • Terms
  • Site map
  • llms.txt

Everyday

  • Images
  • Video
  • Audio
  • PDF & files
  • Text
  • QR codes
  • Units & math
  • Time & dates
  • Color
  • Passwords & IDs
  • Device tests
  • Sun & moon

For developers

  • JSON
  • Encoding
  • Regex & cron
  • Web & auth
  • Hashing & encryption
  • Config files
  • Network
  • Browser
  • AI
  • Fake data
© Nutter Toolsnutter.tools
  1. Home
  2. Units & math
  3. Short-Circuit current
Your files stay on your device

Short-Circuit current

Estimate prospective fault current at a board from transformer, source, and cable data, and compare it with device ratings.

This tool is in beta

Still being tested. If a result looks wrong, tell us.

Report a problem

Enter a transformer to estimate the prospective fault current.

This is the infinite-bus method with a series correction, not a full IEC 60909 study. It sums source, transformer, and cable impedances and reports c x Un / (sqrt(3) x Z) as a three-phase figure; there is no motor contribution, no arc resistance, and no DC time-constant decay. The voltage factor c (1.05 for 400 V supplies under IEC 60909) prices the highest-voltage condition. Cable resistance carries a linear temperature correction from 20 degrees C, and the asymmetric peak uses the IEC factor k = 1.02 + 0.98 x e^(-3R/X), which reaches 2 x sqrt(2) x I on a purely inductive path. A pass against Icu says the device can break the prospective current at that point; it is not a coordination study and not a design certificate. Small transformers also feed large faults through their terminals: check the device rating where it is actually installed.

Source and cable

More settings▾
Material

Numbers stay within ±1,000,000,000. Leave the upstream fault level blank for an infinite bus, and leave the cable fields blank to fault the transformer terminals.