Your files stay on your device

# Motor slip calculator

Get synchronous speed, slip in rpm and percent, and rotor frequency for an induction motor, with a plain reading of the loading.

Enter a measured speed to read the slip.

An induction motor turns a little slower than the rotating field, and that gap is the slip. The rotor currents it produces have a frequency of their own: slip fraction times supply frequency, so a 4% slip on 50 Hz means 2 Hz in the rotor bars. Typical full-load slip runs under 1% on large machines to 5% or more on small ones, per IEC 60034-1 rating practice. Speeds above the field are kept and reported as negative slip: the machine is then driven, not driving.
Options

## More unit & math tools

- [555 timer calculator](/converters/555-timer-calculator)
- [4-20 mA scaling](/converters/4-20ma-scaling-calculator)
- [Unit converter](/converters/units)
[All unit & math tools](/converters)

Was this tool useful?
YesNo

---

Canonical HTML: https://nutter.tools/converters/motor-slip-calculator
Markdown version: https://nutter.tools/converters/motor-slip-calculator.md
Plain-text version: https://nutter.tools/converters/motor-slip-calculator.txt