Your files stay on your device 555 timer calculator Astable frequency and duty from RC values, resistors for a target, or a monostable pulse width. Choose a mode and enter the timing components. Timing follows the standard bipolar-555 equations: the astable charges through R1+R2 and discharges through R2 alone, so its duty cycle always sits above 50%, and the monostable pulse is 1.1 times R times C. Findings flag the component choices that tend not to work in real hardware: discharge resistance under 1 kΩ, timing resistance past 10 MΩ, capacitors under 500 pF or deep into electrolytic territory, frequencies past a bipolar NE555, and monostable pulses under 10 µs. Options More unit & math tools - Unit converter (/converters/units) - Primes, GCD, and LCM (/converters/primes) - Aspect ratio and DPI (/converters/aspect-ratio) All unit & math tools (/converters) Was this tool useful? YesNo Canonical HTML: https://nutter.tools/converters/555-timer-calculator Markdown version: https://nutter.tools/converters/555-timer-calculator.md Plain-text version: https://nutter.tools/converters/555-timer-calculator.txt Agent index: https://nutter.tools/llms.txt